Evaluation of Prefabricated Edge Drains (PED) in Ohio

Evaluation of Prefabricated Edge Drains (PED) in Ohio
Author :
Publisher :
Total Pages : 124
Release :
ISBN-10 : NWU:35556028264364
ISBN-13 :
Rating : 4/5 ( Downloads)

Book Synopsis Evaluation of Prefabricated Edge Drains (PED) in Ohio by : Andrew G. Heydinger

Download or read book Evaluation of Prefabricated Edge Drains (PED) in Ohio written by Andrew G. Heydinger and published by . This book was released on 1998 with total page 124 pages. Available in PDF, EPUB and Kindle. Book excerpt: An investigation was conducted to evaluate prefabricated edge drain (PED) construction procedures and to assess the condition of PEDs installed in Ohio between 1988 and 1993. The research included a survey of department of transportation engineers in other states and Ohio Department of Transportation (ODOT) design and construction engineers. The condition of PEDs installed in Ohio was evaluated at six sites throughout Ohio by excavating short sections of PEDs for visual inspections and permittivity testing. A video borescope with a 25-ft (7.6-m) long fiber optic cable was used to investigate the in situ condition of the PED. Permittivity testing of the PED fabric was conducted in the field on PED samples removed from the excavations. Specifications for installing PED vary considerably among the states using PED. ODOT current specifications require placing the PED on the outside of the trench and using a granular backfill. Problems that have been reported include deformation of the PED core, compression of the filter fabric into the core, blinding and clogging of the filter, sedimentation of the core and blockage of drainage outlets. In most cases, the problems were considered minor. The problems cited above were observed at all six sites during the video borescope inspections. In spite of problems with the filter fabric, the permittivity of the filter fabric was not significantly reduced. The problems with PED result in reduced drainage capacity. However, the PEDs are effective in providing drainage provided the drainage outlets are not blocked. Construction specifications should be observed to minimize problems. Maintenance personnel should inspect drainage outlets on a regular basis to ensure that the outlets are not blocked.

Evaluation of Prefabricated Edge Drains (PED) in Ohio Related Books

Evaluation of Prefabricated Edge Drains (PED) in Ohio
Language: en
Pages: 124
Authors: Andrew G. Heydinger
Categories: Drainage
Type: BOOK - Published: 1998 - Publisher:

GET EBOOK

An investigation was conducted to evaluate prefabricated edge drain (PED) construction procedures and to assess the condition of PEDs installed in Ohio between
Laboratory Evaluation of Prefabricated Highway Edge Drains
Language: en
Pages: 283
Authors: Ahmed Mohamed Elsharief
Categories: Geotextiles
Type: BOOK - Published: 1992 - Publisher:

GET EBOOK

Ohio Documents
Language: en
Pages: 248
Authors:
Categories: Government publications
Type: BOOK - Published: 1995 - Publisher:

GET EBOOK

Design and Construction of Bridge Approaches
Language: en
Pages: 56
Authors: Harvey E. Wahls
Categories: Technology & Engineering
Type: BOOK - Published: 1990 - Publisher: Transportation Research Board

GET EBOOK

Includes case histories of the Dumbarton Bridge (San Francisco Bay, Calif.), the Rainier Avenue Embankment (Seattle, Wash.) and the Gallows Road Grade Separatio
Onsite Wastewater Treatment Systems Manual
Language: en
Pages: 378
Authors:
Categories: Sewage
Type: BOOK - Published: 2002 - Publisher:

GET EBOOK

"This manual contains overview information on treatment technologies, installation practices, and past performance."--Introduction.