Simulation of Single-Particle Inductively Coupled Plasma-Mass Spectrometry

Simulation of Single-Particle Inductively Coupled Plasma-Mass Spectrometry
Author :
Publisher : Open Dissertation Press
Total Pages :
Release :
ISBN-10 : 1361335130
ISBN-13 : 9781361335130
Rating : 4/5 (130 Downloads)

Book Synopsis Simulation of Single-Particle Inductively Coupled Plasma-Mass Spectrometry by : Kin-Ho Lee

Download or read book Simulation of Single-Particle Inductively Coupled Plasma-Mass Spectrometry written by Kin-Ho Lee and published by Open Dissertation Press. This book was released on 2017-01-26 with total page pages. Available in PDF, EPUB and Kindle. Book excerpt: This dissertation, "Simulation of Single-particle Inductively Coupled Plasma-mass Spectrometry" by Kin-ho, Lee, 李健豪, was obtained from The University of Hong Kong (Pokfulam, Hong Kong) and is being sold pursuant to Creative Commons: Attribution 3.0 Hong Kong License. The content of this dissertation has not been altered in any way. We have altered the formatting in order to facilitate the ease of printing and reading of the dissertation. All rights not granted by the above license are retained by the author. Abstract: Time-resolved Inductively Coupled Plasma -Mass Spectrometry (ICP-MS) is a versatile tool for the analysis of single particles such as air particles, nanoparticles, and biological cells. In this study, the processes of particle vaporization and analyte atom diffusion and ionization in the ICP were investigated using computer simulation. Gold nanoparticles of particle diameter 10 to 250 nm were used as the model particle. The parameters of the model were optimized with respect to the experimental data. The relative importance of these parameters was investigated. Simulated ICP-MS intensity versus sampling depth for different particle size was calculated. Two models of particle vaporization, namely heat-transfer-limited and mass-transfer-limited, were adopted to describe the kinetics of vaporization of the gold nanoparticles. The rate of particle vaporization of the limiting model in each 5-s time step was used in the simulation. The heat-transfer-limited process dominates at lower position of the ICP. The mass-transfer-limited process takes over at sampling depth of 4mm or above where the ICP temperature is higher than 4000K. The simulation assumed that the gold atoms vaporized from the particle in each time step diffuse independently. The number density of the gold atoms was calculated using the Chapman-Enskog diffusion theory for each subsequent time step. The degree of ionization of the gold atoms was estimated using Saha equation and was assumed to be dependent on the plasma temperature only. The simulated ICP-MS intensity at any instant was the sum of the gold ions in the ion plumes from all previous time steps that pass through a 1-mm sampler cone. The effects of several simulation parameters on the calculated ICP-MS intensity were investigated. The simulation depth profile of ICP-MS intensity of 100-nm gold nanoparticle was compared to the experimental ICP-MS depth profile. The ICP-MS intensity depends strongly on the ionization temperature of the plasma and the evaporation coefficient of the analyte. The ICP temperature profile, gas velocity, ionization temperature and evaporation coefficient were optimized for the best fit of simulated results to the experimental data. Simulated calibration curves of gold nanoparticles of nominal diameter of 10 nm to 250 nm are non-linear at any sampling depth. The calibration curve rolls off at high mass due to incomplete vaporization of the larger particles in the ICP. The calibration curve at high sampling depth concaves upward in the low mass range because of significant diffusion loss of the analyte atoms for the small particles. DOI: 10.5353/th_b5177356 Subjects: Particles - Analysis Inductively coupled plasma mass spectrometry

Simulation of Single-Particle Inductively Coupled Plasma-Mass Spectrometry Related Books

Simulation of Single-Particle Inductively Coupled Plasma-Mass Spectrometry
Language: en
Pages:
Authors: Kin-Ho Lee
Categories:
Type: BOOK - Published: 2017-01-26 - Publisher: Open Dissertation Press

GET EBOOK

This dissertation, "Simulation of Single-particle Inductively Coupled Plasma-mass Spectrometry" by Kin-ho, Lee, 李健豪, was obtained from The University of H
Simulation of Single-particle Inductively Coupled Plasma-mass Spectrometry
Language: en
Pages: 180
Authors: 李健豪
Categories: Inductively coupled plasma mass spectrometry
Type: BOOK - Published: 2013 - Publisher:

GET EBOOK

STUDIES OF SINGLE-PARTICLE IND
Language: en
Pages: 216
Authors: Wan-Waan Lee
Categories: Science
Type: BOOK - Published: 2017-01-26 - Publisher: Open Dissertation Press

GET EBOOK

This dissertation, "Studies of Single-particle Inductively Coupled Plasma Mass Spectrometry" by Wan-waan, Lee, 李雲鬟, was obtained from The University of Ho
Studies of Single-particle Inductively Coupled Plasma Mass Spectrometry
Language: en
Pages: 364
Authors: 李雲鬟
Categories: Inductively coupled plasma mass spectrometry
Type: BOOK - Published: 2014 - Publisher:

GET EBOOK

Single Particle Analysis by Time-Resolved Icp-MS Measurement
Language: en
Pages:
Authors: Kwok-On Lui
Categories:
Type: BOOK - Published: 2017-01-26 - Publisher:

GET EBOOK

This dissertation, "Single Particle Analysis by Time-resolved ICP-MS Measurement" by Kwok-on, Lui, 呂國安, was obtained from The University of Hong Kong (Pok