The failure of the FiReControl project

The failure of the FiReControl project
Author :
Publisher : The Stationery Office
Total Pages : 56
Release :
ISBN-10 : 0215561546
ISBN-13 : 9780215561541
Rating : 4/5 (541 Downloads)

Book Synopsis The failure of the FiReControl project by : Great Britain: Parliament: House of Commons: Committee of Public Accounts

Download or read book The failure of the FiReControl project written by Great Britain: Parliament: House of Commons: Committee of Public Accounts and published by The Stationery Office. This book was released on 2011-09-20 with total page 56 pages. Available in PDF, EPUB and Kindle. Book excerpt: FiReControl was an ambitious project with the objectives of improving national resilience, efficiency and technology by replacing the control room functions of 46 local Fire and Rescue Services in England with a network of nine purpose-built regional control centres using a national computer system. The project was launched in 2004, but following a series of delays and difficulties, was terminated in December 2010 with none of the original objectives achieved and a minimum of £469 million being wasted. The Department attempted, without sufficient mandatory powers, to impose a single, national approach on locally accountable Fire and Rescue Services who were reluctant to change the way they operated. There were no basic project approval checks and balances - decisions were taken before a business case, project plan or procurement strategy had been developed and tested. The result was hugely unrealistic forecast costs and savings, naève over-optimism on the deliverability of the IT solution and under-appreciation or mitigation of the risks. Fundamentals of project management were absent: the centres were constructed and completed whilst there was considerable delay in even awarding the IT contract, let alone developing the essential IT infrastructure. There was a high turnover of senior managers although none have been held accountable for the failure. The IT contract went to a company with no direct experience of supplying the emergency services. £84.8 million is now earmarked to meet the project's original objectives, to improve resilience, efficiency and interoperability within the Fire and Rescue Service but there is no certainty this will provide value for money.

The failure of the FiReControl project Related Books

The failure of the FiReControl project
Language: en
Pages: 56
Authors: Great Britain: Parliament: House of Commons: Committee of Public Accounts
Categories: Business & Economics
Type: BOOK - Published: 2011-09-20 - Publisher: The Stationery Office

GET EBOOK

FiReControl was an ambitious project with the objectives of improving national resilience, efficiency and technology by replacing the control room functions of
The failure of the FiReControl project
Language: en
Pages: 40
Authors: Great Britain: National Audit Office
Categories: Technology & Engineering
Type: BOOK - Published: 2011-07 - Publisher: The Stationery Office

GET EBOOK

The project to replace the 46 Fire and Rescue Services' local control rooms across England with nine purpose-built regional control centres linked by a new IT s
Information Circular
Language: en
Pages: 326
Authors:
Categories: Mines and mineral resources
Type: BOOK - Published: 1993 - Publisher:

GET EBOOK

Public Service on the Brink
Language: en
Pages: 299
Authors: Jenny Manson
Categories: Business & Economics
Type: BOOK - Published: 2012-03-13 - Publisher: Andrews UK Limited

GET EBOOK

The contributors to this book mount a robust defence of the concept and practice of public service at a crucial time for its future. They question the ill-conce
Three Mine Fire Control Projects in Northeastern Pennsylvania
Language: en
Pages: 768
Authors: H. A. Dierks
Categories: Helium
Type: BOOK - Published: 1971 - Publisher:

GET EBOOK