The Multiple Inert Gas Elimination Technique: Current Methodology at the U.S. Army Institute of Surgical Research

The Multiple Inert Gas Elimination Technique: Current Methodology at the U.S. Army Institute of Surgical Research
Author :
Publisher :
Total Pages : 56
Release :
ISBN-10 : OCLC:74240248
ISBN-13 :
Rating : 4/5 ( Downloads)

Book Synopsis The Multiple Inert Gas Elimination Technique: Current Methodology at the U.S. Army Institute of Surgical Research by :

Download or read book The Multiple Inert Gas Elimination Technique: Current Methodology at the U.S. Army Institute of Surgical Research written by and published by . This book was released on 2002 with total page 56 pages. Available in PDF, EPUB and Kindle. Book excerpt: The intrapulmonary causes of hypoxemia include alveolar hypoventilation, ventilation- perfusion (VA/Q) inequality, shunt, and diffusion limitation to oxygen. In the late 1970s, P.D. Wagner developed the Multiple Inert Gas Elimination Technique (MIGET), a method of assessing VA/Q inequality (VA/Q mismatch) and shunt. It can also be used to measure diffusion limitation. In MIGET, the lung is considered as a set of 50 respiratory units, each with a different VA/Q ratio. Six inert gases of varying solubility are infused, and the arterial, mixed venous, and expired air concentrations of the gases are measured under steady-state conditions. Then, distribution of blood flow and ventilation to each of the 50 compartments is calculated. Although technically challenging, this method can be applied in a wide range of basic and clinical settings, and enables the evaluation Of VA/Q mismatch in a relatively low-risk, non-invasive fashion. This report describes the MIGET methodology from a technical standpoint, as currently performed at this Institute. General set-up; assessment of the gas chromatograph instrument's linearity; preparation and infusion of the 6-gas solution; specimen collection; specimen processing, and data analysis are covered in detail. Creation of a new, complex, multi-ramped GC program is described. Instructional videos form part of the multimedia CD-R0M version of this report.

The Multiple Inert Gas Elimination Technique: Current Methodology at the U.S. Army Institute of Surgical Research Related Books

The Multiple Inert Gas Elimination Technique: Current Methodology at the U.S. Army Institute of Surgical Research
Language: en
Pages: 56
Authors:
Categories:
Type: BOOK - Published: 2002 - Publisher:

GET EBOOK

The intrapulmonary causes of hypoxemia include alveolar hypoventilation, ventilation- perfusion (VA/Q) inequality, shunt, and diffusion limitation to oxygen. In
The Multiple Inert Gas Elimination Technique (MIGET)
Language: en
Pages: 329
Authors: Susan R. Hopkins
Categories: Medical
Type: BOOK - Published: 2018-05-26 - Publisher: Springer

GET EBOOK

The Multiple Inert Gas Elimination Technique (MIGET) is a complex methodology involving specialized gas chromatography and sophisticated mathematics developed i
Annual Research Progress Report - US Army Institute of Surgical Research
Language: en
Pages: 830
Authors:
Categories: Acute renal failure
Type: BOOK - Published: 1992 - Publisher:

GET EBOOK

Issues in Extreme Conditions Technology Research and Application: 2011 Edition
Language: en
Pages: 673
Authors:
Categories: Technology & Engineering
Type: BOOK - Published: 2012-01-09 - Publisher: ScholarlyEditions

GET EBOOK

Issues in Extreme Conditions Technology Research and Application: 2011 Edition is a ScholarlyEditions™ eBook that delivers timely, authoritative, and comprehe
Pulmonary Gas Exchange
Language: en
Pages: 88
Authors: G. Kim Prisk
Categories: Science
Type: BOOK - Published: 2013-08-01 - Publisher: Biota Publishing

GET EBOOK

The lung receives the entire cardiac output from the right heart and must load oxygen onto and unload carbon dioxide from perfusing blood in the correct amounts